Chapter
1.10 |
Direct
Burial Jelly Filled Served Steel Wire Armored Outdoor Copper Telecom Cable |

|
Multipair copper cables for direct burial installations for telecom applications
in rodent infested areas.
The cable core is made of twisted pairs which are cabled into groups, jelly filled and
tape wrapped with a polyester binder.
Flooding compound is inserted between the polyester tape and the aluminum moisture
barrier, which is placed over the cable core
and bonded to an inner PE jacket.
A served steel wire armor is wrapped over the inner
jacket and flooded with a water resistant compound. The overall jacket is made of black
PE.
Conductor range, pair count range and applications:
0.5 mm conductors: 2-100 pairs, used mainly in distribution networks.
0.63 mm conductors: 2-100 pairs; 0.9 mm conductors:2-50 pairs, used mainly for long-haul
installations. |
Cable
Construction |
| Conductors |
Solid annealed bare copper
conductors, conforming to ASTM B3 |
| Insulation |
Foam-skin Polyolefin conforming to
ASTM D1248 |
| Cable assembly |
Twisted pairs, cabled into
sub-units and super-units, cabled in a circular form. |
| Filling compound |
Water resistant filling compound,
applied to the gaps between the pairs. |
| Tape wrap |
Non hygroscopic plastic tape,
wrapped with 30% overlap. |
| Flooding compound |
Water resistant flooding compound,
applied between the core wrap and the aluminum foil. |
| Moisture barrier |
200 micron aluminum/copolymer foil
laid longitudinally, bonded to the outer jacket. |
| Inner Jacket |
Black LLDPE compound conforming to
ASTM D1248. |
| Steel armor |
Round galvanized steel wire applied
over the inner jacket and flooded with a water-resistant compound. |
| Outer Jacket |
Black LLDPE compound conforming to
ASTM D1248. |
| Surface marking |
Per request. |
Electrical Parameters |
Basic Conductors:
Solid bare annealed copper |
0.5 mm |
0.63 mm |
0.9 mm |
| DC Resistance @20C, Ohm/Km, Average
Maximum |
92 |
58 |
28 |
| DC Resistance @20C, Ohm/Km,
Absolute Maximum |
96 |
60 |
30 |
Mutual Capacitance
@800 Hz, nF/Km, Average Maximum |
56 |
56 |
59 |
Mutual Capacitance
@800 Hz, nF/Km, Absolute Maximum |
64 |
64 |
65 |
| Capacitance Unbalance @800 Hz,
pF/500m, Between Pairs |
|
| Average Maximum |
275 |
| Absolute Maximum |
800 |
| Insulation Resistance
@500Vdc, GigaOhm·Km Minimum |
1.5 |
| Dielectric Strength, AC
Volts per 1 minute, Pair to Pair |
2000 |
2400 |
3000 |
| Dielectric Strength, AC
Volts per 1 minute, Pair to Ground |
2000 |
2400 |
3000 |
Conductor OD
mm |
WW P/N |
Number of
Pairs |
Overall
Diameter
mm |
Total Weight
Kg/Km |
0.5
|
WTLJ002x05 |
2 |
9.9 |
180 |
| WTLJ005x05 |
5 |
11.7 |
244 |
| WTLJ010x05 |
10 |
12.5 |
429 |
| WTLJ020x05 |
20 |
15.2 |
429 |
| WTLJ030x05 |
30 |
17.1 |
596 |
| WTLJ040x05 |
40 |
18.2 |
683 |
| WTLJ050x05 |
50 |
20.0 |
876 |
| WTLJ100x05 |
100 |
25.0 |
1333 |
|
0.63
|
WTLJ002x06 |
2 |
10.5 |
205 |
| WTLJ005x06 |
5 |
12.7 |
296 |
| WTLJ010x06 |
10 |
13.8 |
357 |
| WTLJ020x06 |
20 |
17.9 |
642 |
| WTLJ030x06 |
30 |
20.3 |
883 |
| WTLJ040x06 |
40 |
21.6 |
1008 |
| WTLJ050x06 |
50 |
23.0 |
1152 |
| WTLJ100x06 |
100 |
29.2 |
1801 |
|
0.9
|
WTLJ002x09 |
2 |
11.5 |
249 |
| WTLJ005x09 |
5 |
14.7 |
395 |
| WTLJ010x09 |
10 |
16.9 |
596 |
| WTLJ020x09 |
20 |
22.1 |
1049 |
| WTLJ030x09 |
30 |
24.3 |
1280 |
| WTLJ040x09 |
40 |
26.0 |
1492 |
| WTLJ050x09 |
50 |
28.0 |
1735 |
|